Portable Chemical Agents Detector |
|
This portable chemical contamination control device used to detect chemical agents G (GA, GB, GD, GF,…), VX and HD in the form of vapor or aerosols.
The Detector is particularly suitable for military use in rough conditions: fast turn on, immediate identification and measurement, single-handed operation, simplicity of use, ability to be turned off without precautions…
The Detector is a flame spectrophotometer. Air containing toxic agents is drawn in and burned to a high temperature in a hydrogen burner. The elements emit rays in their spectral characteristic emissions. The Detector detects the atoms of phosphorus (contained in G, V agents) and sulfur (contained in HD, V agents).
CHARACTERISTICS: |
|
SPECIAL APPLICATION: |
|
When the Alarm Box is connected with the Detector, this set becomes the APACC (portable chemical control and alarm device) for chemical agents: G (GA, GB, GD, GF…),VX (A4), HD. The Alarm Box is fitted to the Detector in place of the battery tray. However, the Detector can still be used at any time as a monitor device for chemical contamination.
The APACC provides an alarm for a predefined dose of toxic agents. This dose equals the quantity of toxic that induces a disease. It is calculated by the APACC: the detector adds the values resulting from the multiplication of the detected instantaneous concentration by the elapsed time.
There is a visible alarm (the red indicator lights up) and an audible alarm (the buzzer sounds).
The information can be relayed up to 400 meters via an alarm deport box using a RS 485 twisted pair link, and up to 1000 meters using a shielded cable via a surveillance station. |
|
Weight - in operation: |
2 kg (4 ½ lbs) |
|
Power supply: |
battery or external supply ( 9-32 V DC) or rechargeable battery |
|
Temperature range - in operation: |
-32°C to +55°C |
|
Temperature range - in storage: |
-39°C to +71°C |
|
Sensitivity in vapors, aerosols, droplets and dust in the air: |
- 10 µg/m3
for all G agents (1.5 ppb) |
|
Sensitivity in liquid form ON SURFACE: |
- Superficial contamination: 3 µg/cm2 of VX
|
|
Sensitivity in water: |
- 30 µg/l of GB - 25 µg/l of VX - 1.5 mg/l of HD |
|
Sensitivity on skin in MEDICAL application: |
- 0.04 µg/cm2 of VX - 0.35 µg/cm2 of HD |
|
Operational up to 10 000 feet altitude (3 000 meters). |
|
|
Network possibilities |
|
|
|