Disaster Shelter |
|
P10 Technical Data <<< Back |
|
1 MT AIR/SURFACE BURST |
*Notes |
Units |
20 psi |
40 psi |
60 psi |
80 psi |
|
Distance From Ground Zero |
~1 |
miles |
1.4 |
0.85 |
0.7 |
0.6 |
|
Radiation Dose-Neutron |
~2 |
rems |
9000 |
60000 |
160000 |
300000 |
|
Radiation Dose-Initial Gamma |
~3 |
rems |
3250 |
20750 |
45000 |
72500 |
|
Radiation Dose-Fallout Gamma |
~4 |
rems |
12000 |
12000 |
12000 |
12000 |
|
Overhead Dose-Neutron |
~5 |
rems |
<1 |
<1 |
<1 |
<1 |
|
Overhead Dose-Gamma |
~6 |
rems |
<1 |
<1 |
<1 |
<1 |
|
Radiation Dose-HEPA |
~7 |
rems |
0 |
0 |
0 |
0 |
|
Entranceway Gamma+Neutron -ctr |
~8 |
rems |
2 |
10 |
26 |
49 |
|
Total Rems In Shelter- ctr |
~9 |
rems |
2-20 |
13-40 |
33-60 |
61-80 |
|
Total Rems In Shelter-bed area |
~10 |
rems |
1-20 |
3-40 |
6-60 |
13-80 |
|
Shelter Internal Pressure |
~11 |
psi |
0.8 |
1.5 |
2.0 |
2.5 |
|
Displacement-Vertical |
~12 |
inches |
1.74 |
3.70 |
4.24 |
5.18 |
|
Displacement-Horizontal |
~13 |
inches |
0.57 |
1.25 |
1.41 |
1.73 |
|
Seismic Equivalent |
~14 |
Richter |
8.5 |
8.5+ |
8.5+ |
8.5+ |
|
Probability Of No Excessive OP |
~15 |
% |
96.2 |
96.8 |
97.1 |
97.2 |
|
Connector Port Diameter |
36 inches |
|
Duration Of Activated Carbon Filter- contaminated environment approx. |
2000 hrs. |
|
Duration Of HEPA Filter- contaminated environment |
240-1000 hrs. |
|
Duration Of Whetlerite Carbon Filter- contaminated environment approx. |
2000 hrs. |
|
Earth Cover At Crown |
96 inches |
|
Entranceway Diameter |
36 inches |
|
Entranceway Horizontal Dimension |
7 ft to center |
|
Entranceway Vertical Dimension |
13 ft |
|
Floor Area |
100 ft2 |
|
Gravity @ 70 lbs/ft3 |
105,000 lbs |
|
Hatch Entry Diameter |
24 inches |
|
Hatch Material |
structural or combat plastic |
|
Hydrostatic Pressures |
84,937 lbs |
|
Installation Approved For Below Water Table |
yes |
|
Max. Command Station Top Lat. X,Y,Z Movement |
3 inches |
|
Max. Command Station Vertical Movement |
3 inch |
|
Max. Translation |
1 inch |
|
O.P. Shelter Rating- No Earth Support |
40 psi |
|
O.P. Shelter Rating-Max. Earth Support |
150 psi |
|
Protection Factor-Gamma (at crown) |
131,200 |
|
Protection Factor-Neutron (at crown) |
1,050,000 |
|
Shelter Material |
structural fiberglass |
|
Shelter Volume |
1337ft3=10,000 gal |
|
Shelter Wall Thickness |
3/4 to 1-1/2 inch nominal |
|
Shelter Weight |
4500 lbs. |
|
Snow Operation |
HEPA Snow tube |
|
Storage volume under floor |
100 ft3 |